ARTICLE 4. Structural Steel Framed Buildings [7250. - 7267.]
Article 4 added by Stats. 1970, Ch. 1498.
§§ 7250–7267 · 18 sections
- § 7250 As used in this article “building” means any multifloor structural steel framed building more than two stories high in the course of construction.
- § 7251 As defined above, these provisions shall apply to buildings erected in tiers or stories and shall not apply to steel framed buildings having large open spans…
- § 7252 The derrick or working floor of every building shall be solidly decked over its entire surface except for access openings.
- § 7253 There shall be a tight and substantial temporary floor within two floors below and directly under that portion of each tier of beams on which erection,…
- § 7254 Temporary floors shall be wood planking of proper thickness, grade and span to carry the working load, but shall not be less than two inches thick, full size…
- § 7255 Provision shall be made to secure temporary flooring against displacement by strong winds or other forces.
- § 7256 Planks shall extend a minimum of 12 inches beyond centerline of their supports at each end.
- § 7257 Wire mesh or plywood (exterior grade) shall be used to cover openings adjacent to columns where planks do not fit tightly.
- § 7258 Metal decking where used in lieu of wood planking shall be of equivalent strength and shall be laid tightly and secured to prevent movement.
- § 7259 Floor planks that are temporarily removed for any reason whatsoever shall be replaced as soon as work requiring their removal is completed or the open area…
- § 7260 Prior to removal of temporary floor plank, employees shall be instructed by assigned supervision the steps to be taken to perform the work safely and in proper…
- § 7261 When gathering and stacking temporary floor plank on a lower floor, in preparation for transferring such plank for use on an upper working floor, the steel…
- § 7262 When gathering and stacking temporary floor planks from the last panel, the steel erector’s personnel assigned to such work shall be protected by safety belts…
- § 7263 The sequence of erection, bolting, temporary guying, riveting and welding shall be such as to maintain the stability of the structural frame at all times…
- § 7264 Where a building is being constructed in sections, each section constitutes a building as defined in Section 7250.
- § 7265 Safety belts and nets shall be required in accordance with Article 24 (commencing with Section 1669) of subchapter 4 of Chapter 4 of Part 1 of Title 8 of the…
- § 7266 No person shall proceed with any work assigned to or undertaken by him, or require or permit any other person to proceed with work assigned to or undertaken by…
- § 7267 The Division of Occupational Safety and Health shall enforce this article.